Grid operators have a ten-day problem on their hands. The January 2026 Arctic outbreaks showed that extreme winter conditions can last that long, and on Nov. 18 the North American Electric Reliability Corporation said the coming winter adds two new strains: an El Niño whose weather is hard to call, and peak-demand forecasts that are higher in 21 of the 23 areas it assesses.
NERC’s 2026-2027 Winter Reliability Assessment does not predict blackouts. It finds that every assessed area has enough resources for a normal winter peak, and then warns about what happens when the cold arrives wide, deep and long.
Demand up in 21 of 23 areas
According to the American Public Power Association’s summary of the report, resource additions, delayed retirements and better cold-weather performance by generators have improved the overall outlook. Against that, winter peak demand forecasts are higher in 21 of the 23 NERC assessment areas, driven mainly by data center expansion and electrification.
NERC President and CEO Jim Robb put the combination bluntly: “the unpredictable weather of El Niño and rapid load growth present unique challenges this winter.” He added that operators are expected to need everything in their tool kit.
Last year’s assessment, released on Nov. 18, 2025, already flagged seven areas at elevated risk and, in the words of NERC’s John Moura, said that “Electricity demand continues to grow faster than the resources being added to the grid,” Power magazine reported. That assessment named areas including NPCC-Maritimes, ERCOT, SERC-East and two in the West.
An El Niño that NOAA expects to be strong
The El Niño in NERC’s title is not a minor footnote. NOAA’s Climate Prediction Center, in its Oct. 8 diagnostic discussion, said El Niño “continues to strengthen, with a strong-to-very strong El Niño likely through January-March 2027,” a chance it put at greater than 83 percent. A strong El Niño shifts the odds on winter temperatures and storm tracks, but it does not guarantee any specific outcome in any one city, which is why NERC calls it unpredictable.
The assessment’s own list of advice reflects that uncertainty. Reliability coordinators, balancing authorities and transmission operators are told to review seasonal operating plans and shortfall communication protocols, assuming extreme conditions could last 10 days or more. Balancing authorities are warned that short-term load forecasts may underestimate demand in extreme cold, and that they should act early on reserve deficiencies.
Gas pipelines as the weak link
Several areas face elevated risk of fuel supply shortfalls for gas-fired generation during prolonged cold or when pipelines are constrained locally. The Pacific Northwest is the region the summary names. Mark Olson, NERC’s manager of reliability assessments, said that “gas-fired generators in the Pacific Northwest are predominantly single-fuel,” and that “Regionally constrained natural gas infrastructure limits available fuel for generators during cold snaps.”
This year’s assessment includes a new analysis of natural gas system risks and trends. Its recommendations to generator owners are practical: complete winter readiness plans before December, deploy weatherization early and keep cold-weather mitigations in place during storms. Gas generators are told to plan fuel purchases around holiday weekends, because purchase deadlines can fall before the holiday.
State and provincial regulators are asked to share utility and pipeline notices, promote conservation appeals and support requested environmental and transportation waivers. Operators are told to run generator fuel surveys, stay in contact with pipeline operators and prepare for flow orders, the pipeline instructions that can limit how much gas a plant receives when the system is stretched.
What January 2026 taught the planners
A joint review by the Federal Energy Regulatory Commission, NERC and the regional entities, published in September, examined the Jan. 20 to Feb. 10, 2026 Arctic Cold Period, which included Winter Storm Fern from Jan. 24 to 27 and Winter Storm Gianna from Jan. 30 to Feb. 2. Peak coincident generator outages reached 68,169 megawatts on Jan. 26, and U.S. electric demand peaked at 666 gigawatts on Jan. 27. No manual load shed was reported. ERCOT wind outages peaked at 12,896 megawatts, more than double the January 2025 level, and the Department of Energy issued 15 emergency orders under Section 202(c) of the Federal Power Act. Roughly half a million Tennessee Valley Authority distribution customers lost power. National dry gas production fell by as much as 14 percent, and day-ahead load forecasts fell short by 3.9 to 10.5 percent across entities, averaging 4.5 percent.
Coverage of that review in Power Engineering quotes Robb saying that multiple challenges brought the system “close to the edge.” The same article reports that the Energy Information Administration projects record U.S. electricity sales of 4,135 billion kilowatt-hours in 2026, up nearly 2 percent from 2025, and about 4,211 billion in 2027, with data centers and manufacturing the main drivers.
What NERC cannot say is where a ten-day event would strike first. Its assessment names the Pacific Northwest for gas risk and leaves the rest of the elevated-risk list for the full report on NERC’s assessments page.
This article was produced with the assistance of AI and reviewed by Morning Overview editors prior to publication.
More from Morning Overview
- The Justice Department asked courts to undo approvals for three offshore wind farms, one already making power
- Over 20 trillion gallons of rain fell on the Four Corners states and Nevada in two weeks
- 11 engines built to run well past 200,000 miles
- Two Kentucky residents died when a small plane crashed at Missouri’s Lake of the Ozarks, and the NTSB is investigating