Skip to main content

Morning Overview

A Washington State University research reactor overheated its fuel past the allowed limit

A single wrong number in a calculation sent a pulse through the core of Pullman’s university reactor hotter than its operating rules allow. On Nov. 13, the Washington State University research reactor reached an estimated peak fuel temperature of about 870 degrees Celsius, above its 830 degree limit for pulsing.

Read next on Morning Overview: Microsoft says its November Windows security updates are breaking printing for some users

The reactor shut itself down, as designed, and the university told the Nuclear Regulatory Commission the same day. Initial calculations indicate the separate safety limit, 1,000 degrees Celsius for standard fuel, was not exceeded.

Inside the NRC event report

The account comes from NRC Event Notification 58535, published in the commission’s report for Nov. 16. The event occurred at about 11:05 a.m. Pacific time on Nov. 13 at the university’s modified TRIGA reactor in Pullman, and the licensee called it an apparent violation of Technical Specification 3.1.2.

During pulse operations, a senior reactor operator prepared a pulse that would insert $1.85 of reactivity, in order to collect data for maximum-reactivity calculations. The operator used reactivity-worth data for control element 4 instead of the correct control element 3. As a result, the pulse rod was set to a cylinder height of 9.13 inches. Using the correct data, the height would have been 7.25 inches.

The pulse inserted an estimated $2.50 of reactivity. “The reactor scrammed due to the inserted pulse,” the report says, and the reactor was shut down at the time of notification. The NRC classified the event as non-emergency.

Two limits, one exceeded

The technical specification at issue exists to cap how much reactivity a pulse can add so that peak temperature in any fuel rod stays at or under 830 degrees Celsius. The estimated 870 degrees therefore exceeded that operating limit by about 40 degrees.

The safety limit is a different, higher line. The report gives it as 1,000 degrees Celsius for standard fuel and 1,150 degrees for 30/20 low-enriched uranium fuel, and says initial calculations show it was not exceeded. WSU completed its conversion to low-enriched 30/20 fuel in October 2008, according to a university history of the reactor.

The report also records that the operator “inadvertently” pulled the wrong element’s data, which makes the cause a data-selection error and not an equipment failure, and the report as read does not describe a fault in the reactor itself. The 40-degree margin over the pulsing limit is small beside the 130 degrees that separated the estimated peak from the 1,000 degree safety limit.

The licensee described the event as reportable within 24 hours, with a follow-up report due within 10 days under the technical specifications. The NRC notification lists Corey Hines as the person who called it in, and WSU’s page names Hines as director of its Nuclear Science Center.

The notification went to the NRC’s headquarters operations center at 18:04 Eastern time on Nov. 13, and the report lists the NRC staff members notified, including the project manager for the office of nuclear reactor regulation, Brooke Gallagher, and Duane Hardesty of the non-power fuel cycle branch.

The reactor and its regulator

The Pullman reactor is rated at 1,000 kilowatts, or 1 megawatt thermal, and holds NRC license R-76, which was renewed on Sept. 30, 2011, according to the NRC’s page for the facility. It produces neutrons and heat, not electricity. WSU’s Nuclear Science Center says it supports isotope production, research radiotracers and teaching, and that more than 55 students have trained as NRC-licensed reactor operators since 2011, according to the center. The reactor is the only one of its kind in Washington state, WSU says.

The core is a rectangular aluminum box suspended from a movable bridge in a pool of deionized light water that serves as coolant, shield and moderator, and motors raise or lower control elements to adjust power, according to the university’s history. The fuel is TRIGA type, which the NRC describes as unique because a moderator, hydrogen, is chemically bonded to the fuel.

First criticality came on March 7, 1961, and the university says about 150 researchers use the reactor each year. In the university’s history piece, Hines, the center’s director, spoke of celebrating 60 years of the reactor producing research for the WSU community.

The NRC’s backgrounder on research and test reactors says the commission regulates 31 operating units, most at universities. It describes a built-in safety feature that reduces reactor power during potential accidents, notes that these reactors operate at low power, and says reactors under 2 megawatts are inspected every two years.

The commission also licenses the people at the controls. Its backgrounder says licensed operators must pass examinations and complete ongoing requalification, and that the NRC inspects security and emergency plans. The WSU reactor’s license was renewed in 2011 after a safety review, and the university says the Department of Energy funded safety and reliability upgrades in summer 2021, including a new epoxy liner for the reactor tank.

What remains open is the follow-up. The report calls the result an apparent violation, and the follow-up due within 10 days of Nov. 13 will carry WSU’s own analysis of how the wrong control element data was used and what changes it will make.

This article was produced with the assistance of AI and reviewed by Morning Overview editors prior to publication.


More from Morning Overview

Morning Overview is reader-supported. Some links in our articles are affiliate links, and we may earn a commission at no extra cost to you. As an Amazon Associate I earn from qualifying purchases. Full disclosure.